<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-29 01-28-41
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 3/5, 36 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 10 kHz 3345 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,9 dBr -1,16 dBr -0,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 1:28, 29.12.2025
RT
"Vertikala - Nejvyraznejsi duchovni a nabozenske udalosti roku..."
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 10 kHz MIN: 6 kHz % above 77 kHz: 0,0000 Acquired: 2025/12/29 1:28:38 Total samples: 3345 Equivalent time: 0:02:47 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: -0,7 dBr MIN: -1,9 dBr AVE: -1,16 dBr % above 0,2 dBr: 0,0 Last value: -1,2 dBr (2025/12/29 1:28:37) 01:14 01:16 01:18 01:20 01:22 01:24 01:26 01:28 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality